-40%

1 LB. / SINTA M2219 3/4" Micro-Fibers Concrete Reinforcing Fiber 1# Bag

$ 2.64

Availability: 732 in stock
  • Brand: GCP Applied Technologies
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Bundle Listing: No
  • Item must be returned within: 30 Days
  • Condition: New
  • Model: SINTA M2219
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: Unknown
  • MPN: Does Not Apply
  • Restocking Fee: No

    Description

    1 LB.  /  SINTA M2219 3/4" Micro-Fibers Concrete Reinforcement  1# Bag (for 1 cubic yard of concrete)
    GPC Applied Technologies (Formerly Grace Microfiber)
    Information from the company:
    SINTA™ M2219 Synthetic fiber for concrete ASTM C1116, ASTM C94 (formerly Grace Microfiber™)  Product DescriptionSINTA™ M2219 is a synthetic fiber for concrete, manufactured from 100% virgin polypropylene in a microfilament form. SINTA™ M2219 is produced on a state-of-the-art production line which is specifically designed to yield an ultrathin concrete reinforcing fiber. SINTA™ M2219 contains over 50 million individual fibers for each 1.0 lb/yd3 dosed. Engineered specifically for use in concrete, it is alkali resistant, non-absorptive and completely noncorrosive. SINTA™ M2219 protects concrete from stresses which cause cracking while the concrete is most vulnerable during the first 24 hours after placement. SINTA™ M2219 complies with ASTM Designation C1116, Standard Specification for Fiber-Reinforced Concrete and Shotcrete, Type III Synthetic Fiber-Reinforced Concrete or Shotcrete. SINTA™ M is ¾ in. (19 mm) in length.UsesSINTA™ M2219 may be used in any application where decreased plastic shrinkage cracking and improved durability are desired. Specifically, such applications include but are not limited to, slabs on grade, pavements, overlays, sloped walls, pools, shotcrete, stucco, precast and prestressed products. It is suggested that this product be used in conjunction with properly compacted base materials and jointing in accordance with ACI guidelines and standards.SINTA™ M2219 may be used as an alternative to welded wire fabric, depending on the application. SINTA™ M2219 may not be used as a replacement for structural or post-crack control steel reinforcement. For temperature or shrinkage post-crack control, please consult a GCP Applied Technologies representative regarding our STRUX® synthetic macro fibers.AdvantagesSINTA™ M2219 uniformly distributes multi-dimensionally through-out the concrete mixture. The extremely high number of fibers in the fresh concrete matrix protects the concrete when its tensile strength is lowest, reducing the formation of plastic shrinkage cracking. This cracking and other internal stresses would otherwise permanently weaken the resulting concrete. The concrete permeability is decreased, while surface characteristics, impact and toughness properties are improved.Technically advanced production techniques make SINTA™ M2219 a highly durable fiber that is virtually invisible in fresh concrete. This minimizes fiber-reinforced concrete finishing concerns while providing the highest level of crack protection available.Product Advantages·       Reduces plastic shrinkage cracking and improves durability·       Protects concrete from stresses that cause cracking·       Provides cost effective control of plastic shrinkage·       Provides overall higher quality of concreteTypical PropertiesSpecific gravity0.91AbsorptionNoneModulus of elasticity500 ksiMelt point320°F (160°C)Ignition point1094°F (590°C)Alkali, acid and salt resistanceHighAddition RatesSINTA™ M2219 may be added to concrete at any point during the batching or mixing process. SINTA™ M2219 may be added to the aggregate during weighing or charging, or to the central mixer or truck before, during, or after charging. The concrete must be mixed at high speed for 5 minutes, or 70 revolutions, after the addition of SINTA™ M2219 to ensure uniform distribution. The standard range of addition for SINTA™ M2219 is 0.5 to 1.0 lb/yd3 (300 to 600 g/m3) of concrete.Compatibility with Other AdmixturesSINTA™ M2219 is compatible with all GCP admixtures. Its action in concrete is purely mechanical and will not affect the hydration process. Each admixture should be added separately.Packaging & HandlingSINTA™ M2219 is available in convenient Concrete-Ready™ Bags which are added, unopened, to the truck drum or central mixer. The specially designed cellulose fiber bags disintegrate and disperse the fibers throughout the mix. SINTA™ M2219 is available in 0.5 lb and 1.0 lb Concrete-Ready Bags in the U.S. and 600 g Concrete-Ready Bags in Canada.SpecificationsFibers shall be ¾ in. (19 mm) microfilament polypropylene fibers as supplied by GCP Applied Technologies, 62 Whittemore Ave., Cambridge, MA 02140. One pound (450 grams) of fibers shall contain no less than 50 million individual fibers, 0.5 lb (225 grams) of fibers shall contain no less than 25 million individual fibers. Required dosage rate shall be as specified by the design engineer or architect. SINTA™ M2219 shall be used in strict accordance with the supplier’s recommendations and within time as specified in ASTM C94. The fiber shall comply with ASTM Designation C1116 Type III 4.1.3. Standard ACI 302 procedures for placing, finishing and curing shall be followed when using SINTA™ M.ReferencesBuilding Codes·       BOCA National Building Codes, SBCCI Standard Building Code, ICBO Uniform Building Code and all supplements as adopted by the Council of American Building OfficialsAmerican Concrete Institute (ACI)·       ACI 544.1 R State of the Art Report of Fiber-Reinforced Concrete·       ACI 302 Guide for Concrete Floor and Slab Construction·       American Society of Testing and Materials (ASTM)—·       ASTM C1116 Standard Specification for Fiber-Reinforced Concrete and Shotcrete·       ASTM C1579 Standard Test Method for Evaluating Plastic Shrinkage Cracking of Restrained Fiber Reinforced Concrete (Using a Steel Form Insert)·      ASTM C94 Standard Specification for Ready-Mixed Concrete